Installation Method of S Type Load Cell

01. Precautions
1) Do not pull the sensor by the cable.

2) Do not disassemble the sensor without permission, otherwise the sensor will not be guaranteed.

3) During installation, always plug in the sensor to monitor the output to avoid drifting and overloading.
02. Installation

1) The load must be aligned with the sensor and centered.

1

2) When the compensating link is not used, the tension load must be in a straight line.

2

3) When the compensating link is not used, the load must be parallel.

3

4) Thread the clamp onto the sensor. Threading the sensor onto the fixture can apply torque, which can damage the unit.

4
5) S-type sensor can be used to monitor the volume in the tank.

5
6) When the bottom of the sensor is fixed on the base plate, the load button can be used.

6
7) The sensor can be sandwiched between two boards with more than one unit.

7
8) The rod end bearing has a splitting or straightening coupler, which can be used to compensate for misalignment.

8